【英語翻訳版】サッシ・ドアの性能を正しくご理解いただくために 10-11(12-13)

概要

  1. Thermal performance
  2. Sound insulation performance
  1. 10
  2. 11

このページのトップへ

このページに含まれるテキストデータ(PDFから抽出された内容)

左ページから抽出された内容
10IIIIIIVIIVVZonePrefectureThermalConductivityKcal/m2·h·°CClassforHousingIHokkaido2.0H-5IIAomori/Iwate/Akita3.0H-4orH-3IIIMiyagi/Yamagata/Fukushima/Ibaraki/Tochigi/Gunma/Niigata/Toyama/Ishikawa/Fukui/Yamanashi/Nagano/Gifu/Shiga4.0H-2orH-1IVSaitama/Chiba/Tokyo/Kanagawa/Shizuoka/Aichi/Mie/Kyoto/Osaka/Hyogo/Nara/Wakayama/Tottori/Shimane/Okayama/Hiroshima/Yamaguchi/Tokushima/Kagawa/Ehime/Kochi/Fukuoka/Saga/Nagasaki/Kumamoto/Oita5.6-VVIMiyazaki/Kagoshima5.6Okinawa5.6■Criteriaforhouseowners(MITIandMCNotificationNo.2)Itspecifiesreferencevaluebydividingregionstosixareas.(3)SelectionguidelinesMinistryofConstructionNotification(No.451)specifiesrecommendedthermalperformanceofthewallopeningforeachsixareainJapandivideduponthevalueofheatingdegreeday*5.Thistableindicatesappropriateclassesforeacharea.Becausetheareaisdividedquiteroughly,theheatingloadvariesdependingonnorthernpartsandsouthernparts,ormountainregionandplainregion,orsunnyplaceandun-sunnyplace.Pleasebeawareofthisfactwhenyouselect.(*5…Refertotheendofthismanual)FeaturesofourproductsFollowingtableshowsthethermalfeatureofourproducts.Performanceclasses--H-1H-3H-4H-5Thermalconductivity(K-value)--4.03.02.52.0Correspondingzone--IIIIIIIIWindowsProductsATMOSII/CTPanelATMOSII/PGPanelThermalIIDuplexMeisterIIAndersenAppliedglassessinglepanePG(Airspace6mm)PG(Airspace12mm)singlepaneLOW-EPG(Airspace12mm)LOW-EPGArgongasfilled(Airspace11mm)MainmaterialsAluminumAluminumAluminum(Thermalbreakmaterial)Double-windows,Outerwindows:Aluminum,Innerwindows:PVCPVCOutdoorside:PVCIndoorside:NaturalwoodDoorProductsPLENUSAluminumDooretc.PLENUSSteelDoorPorteNXRegnumAmbieTXAppliedglassessinglepane,Laminatedglassetc.PG(Airspace6mm)PG(Airspace12mm)LOW-EPG(Airspace12mm)LOW-EPG(Airspace19mm)MainmaterialsAluminumEmbossedsteelsheet+UrethanefoamAluminum+ExpandedPolystyrene+EmbossedsteelsheetAluminum+Insulationpanel+ArtificialandNaturalwoodEmbossedsteelsheet+UrethanefoamFrequentventilationisimportantBecausewindows(door-sets)whichhavehighthermalperformancealsohavehighairtightperformanceingeneral,neglectofventilationcancauseindoorairpollutionoroxygendeficiency,therefore,ventilationisnecessary.Furthermore,ventilationlowershumidityandpreventscondensation.Onepointadvice34
右ページから抽出された内容
11buobuoSoundinsulationperformanceindicateshowmuchsoundcanbepreventedfromcomingfromoutsideorleakingfrominside.Approximateindoornoiselevelisobtainedbydeductingthesoundinsulationperformancelevelofwindowsanddoor-setfromtheoutdoornoiselevel.(Whenmeasuredbyasound-levelmeterwhichdisplaysanapproximatelyequalsoundleveltothelevelfornormalhumanears)Soundiscomposedbyenergyvolume,frequency*6andwaveshape.Soundinsulationperformanceisrepresentedbyaclassificationbasedonhowmuchsoundcanbepreventedinthefrequencybasis.MeasuredvalueisdisplayedwithdB(decibel)*7.(*6and*7…Refertotheendofthismanual)Noiselevel70dB(A)Indoorsoundlevel45dB(A)Soundinsulationperformancelevelofthiswindow25dBkikigagagagagogogogoDescriptionofsoundinsulationperformanceSoundinsulationperformancePerformanceclassificationandresidentialenvironmentForexample,T-1classofwindowsanddoorscaninsulate25dBofnoisefromoutside.ClassesofsoundinsulationperformanceSoundtransmissionclassT-1T-2T-3T-425303540LowerHigher(1)ClassificationofsoundinsulationperformanceClassificationofsoundinsulationperformanceisspecifiedinJISA4706andJISA4702regulationsasshowninthetablebelow.12

このページのトップへ

  • キーワード検索

    • 全てを含む
    • いずれかを含む
    • 全て
    • 現在のカタログから
  • マイバインダー

    マイバインダーは空です。